Media: Water
Temperature: High Temperature
Material: Wcb, Wc6, Wc9, 12crmo, 12crmov, 15CrMo, 15crmov
Connection Form: Welding
Structure: Piston
Pressure: High Pressure
Samples:
US$ 1/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Zhejiang, China
Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (23)
  • Overview
  • Product Description
  • Working Principle
  • Product Features
  • Product Details
  • Product Parameters
  • View of the factory
Overview

Basic Info.

Model NO.
H48H
Function
Non Return
Sealing Form
Self Tight Pressure Sealing
Flow Direction
Unidirection
Standard
ANSI
Application
Industrial Usage, Water Industrial Usage
Transport Package
Plywood Case
Trademark
GOOLE, OEM, ODM
Origin
China(Mainland)
HS Code
8481804090
Production Capacity
10000PCS/Year

Product Description

H48h Forged Type Flanged Feed Water Pump Protection Check Valve
Product Description

H48h Forged Type Flanged Feed Water Pump Protection Check Valve
H48H Forged Type Flanged Feed Water Pump Protection Check Valve is installed on the high pressure feed water pump outlet pipeline of the thermal power unit to prevent backflow of the feed water and protect the feed water pump. The valve cooperates with the pump's small flow to automatically re-circulate the side valve. When the feed pump is at a low load or the exit door is closed, the automatic recirculation bypass valve should be in the open position to ensure the safe operation of the pump. When the empty exhaust check valve opens, the recirculation bypass valve closes automatically. It should not be used for media containing solid particles and high viscosity.

It's Installed on the high-pressure feed water pump outlet pipeline of the thermal power unit to prevent reverse flow of feed water and protect the feed pump. This valve cooperates with the pump's small flow automatic recirculation side valve work, when the feed water pump is in the low load or exit door closed state, automatic recirculation The bypass valve should be in the open position to ensure the safe operation of the pump. When the empty exhaust check valve is opened, the recirculation bypass valve is automatically closed.
Working Principle

Working principle: Open the outlet valve and start the feed pump. After the feedwater reaches a certain pressure, the valve disc will rise to a certain height under the action of the feedwater pressure. Pushing the valve seat will cause the water to flow out. At the same time, due to the rise of the valve disc, The connecting rod rotates, and the discharge valve piece is toggled to move the recirculating blade valve downward and close the emptying port. When the flow of the water supply decreases, the valve disc falls, pushing the connecting rod to open the emptying valve piece, and then opening it again. The circulating valve maintains a small allowable flow rate of the pump. When the pump is stopped, the valve flap automatically falls and closes the valve port passage to prevent the destruction of the high pressure water hammer water supply system.

Product Features

Structural features:

A. The air exhaust check valve cooperates with the recycle bypass valve to maintain the safe operation of the system.
B. When the main valve flap moves up and down and the medium flows backward, the channel is closed by means of the medium pressure and the action of the spring. At this time, the bypass valve is opened. When the main valve flap is fully opened, the bypass valve is closed.
C. The valve flap seal is made of stainless steel surfacing. It is wear-resisting, has strong anti-scratch and reliable sealing.
D. H48H Forged Type Flanged Feed Water Pump Protection Check Valve should be installed vertically.
 
Product Details

 

H48h Forged Type Flanged Feed Water Pump Protection Check Valve
Product Parameters
Trunnion Ball Valve Dimensions
Size in 2 2 1/2 3 4 6 8 10 12 14 16
mm 50 65 80 100 150 200 250 300 350 400
L/L1(RF/BW) in 17.75 20.00 22.75 26.5 36.00 40.25 50.00 56.00 / /
mm 451 508 578 673 914 1022 1270 1422 / /
L2(RTJ) in 17.88 21.25 23.00 26.88 36.50 40.88 50.88 56.88 / /
mm 454 540 584 683 927 1038 1292 1445 / /
H in 7.50 9.00 11.00 14.12 15.75 18.88 20.50 26.38 / /
mm 190 230 280 360 400 480 520 670 / /
W in 24 32 32 32 32 40 40 40 / /
mm 600 800 800 800 800 1000 1000 1000 / /
WT(Kg) RF/RTJ 68 95 120 185 675 1100 1650 2300 / /
BW 54 74 91 122 555 918 1355 2950 / /
 
View of the factory
H48h Forged Type Flanged Feed Water Pump Protection Check Valve
H48h Forged Type Flanged Feed Water Pump Protection Check Valve
 
H48h Forged Type Flanged Feed Water Pump Protection Check Valve
H48h Forged Type Flanged Feed Water Pump Protection Check Valve

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Management System Certification
ISO 9001, ISO 14001
OEM/ODM Availability
Yes