Product: GAY42X Direct Acting Spring Diaphragm Pressure Reducing Valve.| Name of component | Material of component |
| Bottom Cap | WCB |
| Spring | 50CrVA |
| Body | WCB |
| DISC | 2Cr13 |
| Seat Ring | NBR |
| Seat | 2Cr13 |
| Stem | 2Cr13 |
| Cylinder Liner | 2Cr13 |
| Diaphragm | NBR |
| Returnng Spring | 60Si2Mn |
| Bonet | WCB |
![]() |
| DN | external dimension | ||
| L | H | H1 | |
| PN1.0,1.6, 2.5 | PN1.0,1.6,2.5 | PN1.0,1.62.5 | |
| 15 | 160 | 225 | 90 |
| 20 | 160 | 265 | 98 |
| 25 | 180 | 265 | 110 |
| 32 | 200 | 265 | 110 |
| 40 | 220 | 320 | 125 |
| 50 | 250 | 320 | 125 |
| 65 | 280 | 325 | 130 |
| 80 | 310 | 385 | 160 |
| 100 | 350 | 385 | 170 |
| 125 | 400 | 430 | 200 |
| 150 | 450 | 430 | 210 |
| 200 | 500 | 560 | 240 |
| 250 | 650 | 690 | 290 |
| 300 | 800 | 800 | 335 |
| 350 | 850 | 880 | 375 |
| 400 | 900 | 980 | 405 |
| 500 | 950 | 1130 | 465 |
Main Technical Parameters and Indexes of Performance.
| Nominal pressure | PN1.6Mpa | PN2.5Mpa | PN4.0Mpa | PN6.4Mpa |
| Tested pressure of shell | 2.4Mpa | 3.75Mpa | 6.0Mpa | 9.6Mpa |
| Sealing test pressure | 1.6Mpa | 2.5Mpa | 4.0Mpa | 6.4Mpa |
| Maximum upstream pressure | 1.6Mpa | 2.5Mpa | 4.0Mpa | 6.4Mpa |
| Pressure range of outlet | 0.2-1.0Mpa | 0.2-1.6Mpa | 0.2-2.5Mpa | 0.5-3.5Mpa |
| Minimum differential pressure | 0.2Mpa | 0.2Mpa | 0.2Mpa | 0.4Mpa |
| Medium | Steam, water, etc. | |||
| Operating temperature | 425 | |||
| DN | 15 | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | 250 | 300 | 350 | 400 | 500 |
| Cv | 1 | 2.5 | 4 | 6.5 | 9 | 16 | 25 | 36 | 64 | 100 | 140 | 250 | 400 | 570 | 780 | 1020 | 1500 |