Corrosion Resistant Ammonia Globe Valve

Product Details
Customization: Available
Media: Wog
Temperature: High Temperature
Manufacturer/Factory, Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (23)
  • Corrosion Resistant Ammonia Globe Valve
  • Corrosion Resistant Ammonia Globe Valve
  • Corrosion Resistant Ammonia Globe Valve
  • Corrosion Resistant Ammonia Globe Valve
  • Corrosion Resistant Ammonia Globe Valve
  • Corrosion Resistant Ammonia Globe Valve
Find Similar Products
  • Overview
  • Product Description
  • Working Principle
  • Application
  • Product Parameters
  • View of the factory
Overview

Basic Info.

Model NO.
GAJ41B
Material
Alloy Steel Wc6, Wc9
Connection Form
Flange
Pressure
High Temperature
Actuator
Manual
Seal Surface
Metal Sealing
Thread Position of Valve Rod
OS&Y
Usage
Regulation
Application
Industrial Usage
Transport Package
Plywood Case
Trademark
GOOLE, OEM, ODM
Origin
China(Mainland)
HS Code
8481804090

Product Description

Corrosion Resistant Ammonia Globe Valve
Product Description

Corrosion Resistant Ammonia Globe Valve
Ammonia globe valve often require gases such as oxygen, nitrogen, hydrogen, argon, etc. These gases are usually stored in dedicated high-pressure gases. When in use, the gas pressure is reduced to the required range for the experiment through an ammonia globe valve, and then finely adjusted through other control valves to input the gas into the system. The most commonly used pressure reducing valve is the ammonia globe valve, abbreviated as ammonia valve.

Working Principle

The high-pressure chamber of the ammonia valve is connected to the steel cylinder, while the low-pressure chamber serves as the gas outlet and leads to the usage system. The reading of the high-pressure gauge is the pressure of the gas stored in the steel cylinder. The outlet pressure of the low-pressure gauge can be controlled by adjusting the screw.
When using, first turn on the main switch of the steel cylinder, then rotate the pressure regulating screw of the low-pressure gauge clockwise to compress the main spring and drive the film, spring pad, and top rod to open the valve. The high-pressure gas imported in this way enters the low-pressure chamber through throttling and pressure reduction, and is then directed to the working system through the outlet. Rotate the adjusting screw to change the height of the valve opening, thereby adjusting the flow rate of high-pressure gas and achieving the desired pressure value.
Ammonia shut-off valves are equipped with safety valves. It is a device that protects the ammonia pressure reducing valve and ensures its safe use, as well as a signal device for the malfunction of the ammonia pressure reducing valve. If the outlet pressure rises on its own and exceeds a certain allowable value due to valve gasket, valve damage, or other reasons, the safety valve will automatically open for exhaust.

Application

(1) There are many specifications of ammonia globe valve according to different usage requirements. The maximum import pressure is mostly, and the minimum import pressure is not less than 2.5 times the export pressure. There are many specifications for export pressure, generally, with a maximum export pressure of.
(2) When installing ammonia globe valve, it should be determined whether their connection specifications are consistent with the joints of the system being used. The ammonia shut-off valve adopts a hemispherical connection, and the two are fully matched by tightening the nut. Therefore, both hemispheres should be kept smooth during use to ensure good airtightness. Before installation, high-pressure gas can be used to blow away dust. If necessary, materials such as polytetrafluoroethylene can also be used as gaskets.
(3) Ammonia globe valve should be strictly prohibited from coming into contact with grease to avoid fire accidents.
(4) When stopping work, the residual air in the pressure reducing valve should be released completely, and then the adjusting screw should be loosened to prevent the elastic element from being deformed under long-term pressure.
(5) Ammonia globe valve should avoid impact and vibration, and should not come into contact with corrosive substances.
The usage method and precautions of these ammonia globe valve are basically the same as those of ammonia globe valve. However, it should also be pointed out that specialized ammonia valves are generally not used for other gases. To prevent misuse, some ammonia valves use special connection ports between them and steel cylinders. For example, both hydrogen and propane use left threaded threads, also known as reverse threads, and special attention should be paid during installation.

Product Parameters

Corrosion Resistant Ammonia Globe Valve

 
 
DN
L α H DO PNl.6/MPa PN2.5/MPa
D D1 D D1
50 250 37o30' 334 250 58 50 64 4g
65 270 37o30' 439 250 75 65 82 67
80 280 37o30' 495 300 91 79 95 77
100 300 37o30' 575 350 11O 97 117 101
125 325 37o30' 587 350 136 121 144 126
150 350 37o30' 607 350 163 146 172 158
200 400 37o30' 740 400 223 202 223 202
250 450 37o30' 863 400 278 254 278 254
300 500 37o30' 990 400 330 305 330 305
350 550 37o30' 1137 500 382 352 382 352
400 600 37o30' 1523 500 432 399 432 39g
450 650 37o30' 1618 600 485 451 485 451
500 700 37o30' 1657 600 535 501 535 499
600 800 37o30' 1746 700 636 601 636 599
 
DN L D α PN4.0MPa PN6.4/MPa PN10.0MPa
D1 H D0 D1 H DO D1 H D0
50 250 64 37o30' 49 345 300 50 350 300 49 350 300
65 270 83 37o30' 67 441 300 66 447 300 64 447 300
80 280 96 37o30' 79 495 350 77 499 350 75 499 350
100 300 117 37o30' 101 575 350 99 582 400 87 582 400
125 325 144 37o30' 126 587 400 129 590 400 125 590 400
150 350 172 37o30' 152 607 400 150 611 450 145 611 450
200 400 223 37o30' 200 740 450 198 745 550 190 747 550
250 450 278 37o30' 252 863 550 246 867 650 236 869 650
300 500 330 37o30' 302 1008 650 294 1008 750 282 1013 750
350 550 382 37o30' 350 1142 750 342 1148 800 334 1148 850
400 650 432 37o30' 397 1527 850 387 1531 900 377 1533 950
View of the factory
Corrosion Resistant Ammonia Globe Valve
Corrosion Resistant Ammonia Globe Valve
 
Corrosion Resistant Ammonia Globe Valve
Corrosion Resistant Ammonia Globe Valve

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier