J762y Hydraulic Feed Water Heater Isolation Valve

Goole Valve technology Co., Ltd.
  • Audited Supplier
  • 12 yrs

Contact Supplier

Still deciding? Get samples of $ !
Request Sample

Product Highlights

  • Fast Hydraulic Control: Full hydraulic control system with switching time as fast as 2 seconds.
  • Impact Protection Design: Hydraulic cylinder features a damper cone to protect piping and valve seats.
  • Adjustable Flow Direction: Z-type or angle-type body allows 180-degree adjustment of bypass direction.
  • High-Pressure Resistance: Designed for high pressure applications with nominal pressures up to 30.0 MPa.
  • Durable Material Options: Constructed from WCB, A105, or WB36 steel for supercritical unit suitability.
  • Safety Function: Ensures safe disconnection of high pressure heaters during malfunctions.
  • Flexible Configuration: Electric inlet/outlet valves available to simplify system design.
  • Wide Size Range: Available in nominal diameters DN 175, 225, 275, and 300mm.

Product Images of J762y Hydraulic Feed Water Heater Isolation Valve

J762y Hydraulic Feed Water Heater Isolation Valve
J762y Hydraulic Feed Water Heater Isolation Valve pictures & photos
J762y Hydraulic Feed Water Heater Isolation Valve
J762y Hydraulic Feed Water Heater Isolation Valve pictures & photos
J762y Hydraulic Feed Water Heater Isolation Valve
J762y Hydraulic Feed Water Heater Isolation Valve pictures & photos
J762y Hydraulic Feed Water Heater Isolation Valve
J762y Hydraulic Feed Water Heater Isolation Valve pictures & photos
J762y Hydraulic Feed Water Heater Isolation Valve
J762y Hydraulic Feed Water Heater Isolation Valve pictures & photos
J762y Hydraulic Feed Water Heater Isolation Valve
J762y Hydraulic Feed Water Heater Isolation Valve pictures & photos
J762y Hydraulic Feed Water Heater Isolation Valve
  • J762y Hydraulic Feed Water Heater Isolation Valve
  • J762y Hydraulic Feed Water Heater Isolation Valve
    J762y Hydraulic Feed Water Heater Isolation Valve
  • J762y Hydraulic Feed Water Heater Isolation Valve
    J762y Hydraulic Feed Water Heater Isolation Valve
  • J762y Hydraulic Feed Water Heater Isolation Valve
    J762y Hydraulic Feed Water Heater Isolation Valve
  • J762y Hydraulic Feed Water Heater Isolation Valve
    J762y Hydraulic Feed Water Heater Isolation Valve
  • J762y Hydraulic Feed Water Heater Isolation Valve
    J762y Hydraulic Feed Water Heater Isolation Valve
  • J762y Hydraulic Feed Water Heater Isolation Valve
    J762y Hydraulic Feed Water Heater Isolation Valve

Find Similar Products

Product Description

J762Y Hydraulic Feed Water Heater Isolation Valve
Product Description

J762y Hydraulic Feed Water Heater Isolation Valve

The high pressure heater inlet valve is installed at the inlet of the high pressure heater. When the high pressure heater malfunctions, the water level exceeds the allowable water level, and the water supply is switched to the bypass emergencyly to ensure the safe disconnection of the high pressure heater, thereby protecting the high pressure heater. .
Specification

High pressure heater inlet valve main model specifications:
Model: J762Y, J962Y, J764Y, J964Y

Nominal diameter: DN 175,225,275,300mm
Nominal pressure: PN 20.0, 25.0, 30.0mpa

Product Features

1. Full hydraulic control system: fast action, and the fastest switching time up to 2S.
2. Electric inlet valve and electric outlet valve can also be selected: The operation time is slightly longer, but 2 pneumatic quick-open valves can be omitted, simplifying the system design.
3. The hydraulic cylinder has a damper cone to protect the system piping and valve seat from impact.
4. The valve body is Z type or angle type, and the bypass direction can be adjusted within 180 degrees.
5. The valve body is cast or monolithic forged. Material: WCB, A105 or WB36 (15NiCuMoNb5). The WB36 valve body is more suitable for the use of supercritical and higher pressure units.

Product Details

J762y Hydraulic Feed Water Heater Isolation Valve

J762y Hydraulic Feed Water Heater Isolation Valve

Body High-quality carbon steel, Bonnet: High-quality carbon steel
Valve Carbide, Seat: Carbide
Valve stem chrome molybdenum steel, sealing ring: reinforced flexible graphite
Packing Flexible Graphite, Bracket: Carbon Steel
View of the factory
   J762y Hydraulic Feed Water Heater Isolation Valve
Product Photo

J762y Hydraulic Feed Water Heater Isolation Valve
Packaging & Shipping

J762y Hydraulic Feed Water Heater Isolation Valve

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR2331467". Items marked "verified" are certified.

Watch Video
Watch Video
Goole Valve technology Co., Ltd.
Goole Valve technology Co., Ltd.
Goole Valve technology Co., Ltd.
Goole Valve technology Co., Ltd.
Goole Valve technology Co., Ltd.
Goole Valve technology Co., Ltd.
Goole Valve technology Co., Ltd.
Goole Valve technology Co., Ltd.

About Our Factory & Business Background

Address
He-Yi Industiral Zone, Oubei Town, Yongjia, Wenzhou, Zhejiang, China
Terms of Payment
LC, T/T, Western Union, Money Gram
International Commercial Terms(Incoterms)
FOB, EXW, CFR, CIF, DAT, DDP, DAP
Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
Nearest Port
Ningbo, Shanghai

Our Production Capability & Technical Expertise

Main Products
Safety Valve, Ball Valve, Control Valve, Steam Trap, DIN Valve, Strainer, Gate Valve, Globe Valve, Check Valve, Pressure Reducing Valve

Our Industry Experience & Global Business Record

Export Year
2009-07-09
Main Markets
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, Eastern Asia, Western Europe

FAQ

What is the maximum switching time for this valve?
The full hydraulic control system ensures fast action, with the fastest switching time reaching up to 2 seconds.
What materials are available for the valve body?
The valve body can be made of WCB, A105, or WB36 (15NiCuMoNb5). WB36 is particularly suitable for supercritical and higher pressure units.
How does the valve protect the system from damage?
The hydraulic cylinder is equipped with a damper cone designed to protect the system piping and valve seat from impact.
What are the nominal pressure ratings?
The nominal pressure ratings are PN 20.0, 25.0, and 30.0 MPa.
Can the flow direction be adjusted?
Yes, the valve body is available in Z-type or angle-type configurations, allowing the bypass direction to be adjusted within 180 degrees.
What is the primary function of this valve?
It serves as a high pressure heater inlet valve that ensures safe disconnection of the heater by switching water supply to a bypass emergency when water levels exceed allowable limits.
What are the available nominal diameters?
The available nominal diameters are DN 175, 225, 275, and 300mm.
Are electric valves an option?
Yes, electric inlet and outlet valves can be selected. Although the operation time is slightly longer, they allow for the omission of 2 pneumatic quick-open valves, simplifying system design.

Send your message to this supplier

Contact Information
Recipient
Message

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now